# Rotator Repair using a Bio-Composite Scaffold

Rotator Repair using a Bio-Composite (BioBrace) Scaffold for Soft Tissue Augmentation

## Summary

This technique video demonstrates the benefits of adding a bio-composite scaffold to a large rotator cuff repair to reinforce the repair and help prevent suture-tissue pull-through.

## Transcript

433 words · 4 min · automatically transcribed (aws-transcribe) and not checked by a person; it may contain errors, particularly in names, drugs and dosages. The recording is the source.

[0:00] The following video demonstrates an arthroscopic Rotator cuff repair technique utilizing a biocomposite scaffold for insufficient tissue quality. The patient is a 51-year-old right-hand dominant laborer with an injury sustained over 10 months ago. His MRI demonstrates a 2.5 centimeter retracted tear with grade 3 atrophy.
[0:22] After preparation of the subacromial space, the tissue quality is evaluated and known to be atrophic and poor.
[0:33] After decorticating the greater tuberosity, two anchors are placed percutaneously into the medial margin of the greater tuberosity.
[0:42] Each of these anchors is equipped with a self-tensioning tape as well as a standard fiber wire suture.
[1:28] After the replacement of the anchors is complete, the tapes are brought as a unit through the Rotator Cuff tissue using a looped suture passing suture.
[1:44] Once the tapes have been passed together, each limb of the fiber wire suture is individually passed through the Rotator Cuff tissue just posterior to the initial tapes.
[1:55] This is again repeated posteriorly with the tapes being passed at the most posterior aspect of the Rotator Cuff Tear, and the remaining two fiber wire sutures pass individually just anterior to this, keeping all four limbs of the fiber wire between the sets of tapes.
[2:12] The two groups of the fiber wire sutures are then tied down together for a medial compression.
[2:17] They are saved for later passage through the biocomposite scaffold.
[2:21] Next, in a suture bridge configuration, one limb of the anterior tapes and one limb of the posterior tapes are brought laterally to the articular margin and secured down using a 5.5 millimeter self punching anchor.
[2:35] This is again repeated posteriorly to complete our double row Rotator cuff repair.
[2:43] Next, the fiber wire sutures are brought out laterally, and each limb is individually passed through the most medial margin of the biocomposite scaffold.
[2:51] The graft is then shuttled back into the joint using a suture passing device.
[3:00] The two limbs of the fiber wire from the anterior portion of the biocomposite scaffold are brought out and tied down in a simple half hitch for compression and stability.
[3:09] This is again repeated posteriorly.
[3:12] Again, using a suture bridge configuration, we take one limb from the anterior portion of the fiber wires and one limb from the posterior out laterally and secure the sound into a third row with a 2.9 millimeter anchor.
[3:25] Care is taken not to over tension this.
[3:31] Once complete, a survey is undertaken of the biocomposite scaffold to ensure there are no edges which need to be tacked down.
[3:43] As noted, this graft has been rehydrated with blood and throughout the process has maintained the blood within the confines of the scaffold.